Vue de la page 0
WARNING
AMEREC Steam Generators are listed by Underwriters Laboratories. The steam generators come assembled
and ready for installation. Check that the size and rating of the generator is suitable for your application, refer
to Steam Room Construction and Generator Sizing Guide (AMEREC document 4211-38).
IMPORTANT
An exhaust fan installed outside the steam
room is strongly recommended to remove
excess steam from the bathroom or shower
area.
AMEREC STEAMBATH GENERATORS
(AK and 3K MODELS)
Note:To be used with the K30,K60,KT60 or R30K Control.
SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
POST "WARNING" LABEL OUTSIDE STEAMBATH FOR SAFETY
WARNINGS. REQUIRED POSTING ON DOOR OF STEAM ROOM
OR ADJACENT TO DOOR FOR ALL COMMERCIAL
INSTALLATIONS.
SECTION 1: GENERAL INFORMATION
AK and 3K Series Installation and Service
Instructions
Electrical grounding is required on
all AMEREC Steambath Generators.
All electrical supplies should be
disconnected when servicing
generator.
All wiring must be installed by a
licensed electrical contractor in
accordance with local and national
codes.
All plumbing must be installed by a
licensed plumber in accordance with
all applicable local and national
codes.
AK series generators are for indoor
use only.
AK series generators are not for
space heating purposes.
Be certain that steambath enclosures
are properly sealed to avoid water
damage from escaping steam. It is
recommended that 100% silicone
caulk be used to seal all pipes and
fittings. Steam must be prevented
from escaping into the wall cavity.
Never shut off the water to a steam
generator that is in use.
Electric Shock Hazard - High voltage
exists within this equipment. There
are no user serviceable parts in this
equipment.
K60/KT60
OR
K30
OR
R30K
Possible Controls
AK GENERATOR
4211-143-A 02-19-10
REDUCE THE RISK OF
1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in
a heated area is capable of causing overheating.
REDUCE THE RISK OF
Use care when entering or exiting the steam room, floor may be slippery.
NOTE:
For additional safety instructions, see owner’s manual.
CAUTION!
Do not contact steam head. Stay at least 12" away
from hot steam escaping from the steam outlet.
OVERHEATING AND SCALDING
2. Supervise children at all times.
3. Check with a doctor before use if pregnant, diabetic, in poor health or
under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs
or medication is capable of causing unconsciousness.
SLIPPING AND FALL INJURY
WARNING
Vue de la page 0
1 2 3 4 5 6 ... 18 19

Résumé du contenu

Page 1 - AMEREC STEAMBATH GENERATORS

WARNINGAMEREC Steam Generators are listed by Underwriters Laboratories. The steam generators come assembledand ready for installation. Check that the

Page 2 - Table of Contents

page 10AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10SECTION 6: WIRING INSTRUCTIONS (continued)SEE DIAGRAMElectrical sho

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

page 11AK and 3K Series Installation and Service Instructions4211-143-A 02-19-101/8" TO 3/8"LEVEL PROBEDIAGRAM 15 DIAGRAM 16 DIAGRAM 17HE

Page 4 - DIAGRAM 3

page 12AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10D. LEVEL PROBE REPLACEMENT:Disconnect power from the unit. Remove t

Page 5

page 13AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10The AK Generator design may incorporate several modification option

Page 6 - DIAGRAM 9 DIAGRAM 10

page 14AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKENControl "ON".

Page 7

page 15AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10 & "" ! ' # " !  $%&

Page 8

page 16AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10• For assistance or parts ordering,please contact your local AMEREC

Page 9 - DIAGRAM 14

page 17AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10

Page 10 - SECTION 8: SERVICE

page 18AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10

Page 11 - DIAGRAM 20

page 19AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10P.O. Box 2258, Woodinville WA 98072425-951-1120 Fax: 425-951-1130em

Page 12 - 4211-143-A 02-19-10

page 2AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10Section Description PageImportant Safety Instructions 22 Select Moun

Page 13

page 3AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10IMPORTANT SAFETY INSTRUCTIONS1. READ AND FOLLOW ALL INSTRUCTIONS.2.

Page 14

page 4AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10WATER SHUT-OFF VALVEOPTIONAL FILTERDO NOT CONNECT TO WATERSUPPLY WIT

Page 15

page 5AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10SEE DIAGRAMSThe AMEREC steam generator can be hung on a wallor sit o

Page 16 - PARTS AND / OR RETURNS:

page 6AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10DIAGRAM 5 DIAGRAM 6CONTROLHOUSINGSEALANT(MUST FILL GROUTLINE FOR TIL

Page 17

page 7AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10SEE DIAGRAMSAll plumbing shall be installed by a licensed plumberand

Page 18

page 8AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10The pressure relief valve must beinstalled in such a fashion that th

Page 19

page 9AK and 3K Series Installation and Service Instructions4211-143-A 02-19-10SILICONECAULKTEMPERATURESENSORWALL7/8" HOLESENSORCABLEPIGTAILPR